2013 Fiat 500e

Orange · Battery and history report · November 8, 2026

1 stored in 1 modules, 0 active now.

What the car's own computers say about its battery and its history. Read-only: nothing on the car was changed. Each line links to the detail and the evidence.

Not readBattery capacityNot measured yetLog a charge (scripts/charge_log.py) to measure it.CheckFault codes1 stored in 1 modules, 0 active nowThe battery controller has P0AA6-00. The rest are listed with their modules.
Charge (dash)
72%
Pack
387.6V
Cell spread
13mV
Current
-15.4A
Battery temp
22°C
12 V
14.1V

Read from the car at 19:50.

History

Module identification not read.

Recalls

Not looked up. e500 recalls fetches them by model year (no VIN is sent).

Fault codes

Read from every module and never cleared. A module also lists every check it runs; a code counts as a fault only if it has failed, is pending or is confirmed. "Active now" means it failed in this drive cycle.

ModuleCodeStateRecords
Battery controller (BPCM)P0AA6-00Hybrid/EV battery voltage system isolation faultStoredconfirmed, failed since clear1
Every module
  • Telematics unit: no reply to 1902ff at 18DA1FF1
  • ABS / stability control, probably: no reply to 1902ff at 18DA28F1
  • Module 30: no reply to 1902ff at 18DA30F1
  • Body controller, probably: 0 monitored, not failed
  • Vehicle controller (EVCU): 0 monitored, not failed
  • Power inverter (PIM): 0 monitored, not failed
  • Battery controller (BPCM): 0 monitored, not failed
  • On-board charger: 0 monitored, not failed
  • Charging-related, probably: no reply to 1902ff at 18DA47F1
  • Module 48: no reply to 1902ff at 18DA48F1
  • Module 60: no reply to 1902ff at 18DA60F1

Method and evidence

Every figure comes from the car, read with standard read-only diagnostic requests. How each raw value is decoded, and why we believe it:

ReadingModule · data IDEvidence
Cell voltages44 · A100–A108own capture 2026-11-07: 97 u16 mV values; agree with A609-A60B to 1 mV
True charge44 · A602own capture 2026-11-07: fits 5 dash readings within 0.4 %; 240 V energy check 6.5 kW
Highest cell (controller)44 · A609own capture 2026-11-07
Lowest cell (controller)44 · A60Aown capture 2026-11-07
Average cell (controller)44 · A60Bown capture 2026-11-07
Pack current44 · A012own capture 2026-11-07: s16 / 20, negative = charging; -15.45 A x 393 V = 6.1 kW steady on the 6.6 kW charger, ~0.5 A at rest. Scale lead: OBDb gen-2 current (/20)
Capacity (controller's figure)44 · A625own capture 2026-11-07: u16 / 10 = 37.9 Ah, same as module 42 DID 2050; the controller's charge moved 36.4-37.9 Ah per 100 % against the measured current
Charge in since controller fitted44 · A615own capture 2026-11-07: u24 / 10; rose 7.7 Ah while the measured current gave 7.71 Ah
Charge out since controller fitted44 · A616own capture 2026-11-07: u24 / 10, companion of A615; still while charging
Battery module temperatures44 · A200own capture 2026-11-07: 18 x u8 - 40; min/max/mean equal module 42 DIDs 205E-2060. Layout lead: OBDb gen-2 A200

Not read, so not in this report: fault codes, insulation resistance, the controller's history of temperature and charge levels, and anything a dealer tool would need security access for. Assumptions: new capacity 60–67 Ah (published specs disagree), 3.5–4.5 mi/kWh for range.

Recordings used